With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
With Video KT88-3200 Digital 32  Channel EEG  Machine&Mapping System,2 tripods,Brain electric CONTEC - CONTEC
  • SKU: 3.04.005.05.005
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

With Video KT88-3200 Digital 32 Channel EEG Machine&Mapping System,2 tripods,Brain electric CONTEC

$1,399.00 $1,499.00
  • Barcode: 658126910422
DESCRIPTION

Shipping from China 

Introduction


KT88-3200 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors. 

Performance

    32 channels of EEG
    Sampling rate: 200 dots/s
    Accuracy: 12bit
    Input impedance: ≥10MΩ
    Patient leak current: < 10µA
    Noise level: ≤5µVp-p
    CMRR: ≥90dB
    Magnification multiple: 10000
    Filter constant: all digital and free enactment
    Display speed(paper speed): 5, 10, 15, 30, 60, 120 mm/s
    Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV
    Playback speed:1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times
    50Hz interference suppression: ≥30dB
    Safety type:Class II, type BF applied part

    Features

     

      Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling.
      Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system.
      Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform.
      Digital filter system can be set as required, providing different window types
      EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters.
      Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment.
      Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback.
      Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on.
      Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted.
      Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling.
      Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research.
      Integrative image and character report, report can be edited in mode and switched to Word document.
      Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis.
      System parameters and display modes can be set as required, which meets different user’s requirement.
      Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks.
      Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image.
      SpO2 function is optional.

      Accessories

       

      Standard
      EEG lead
      EEG electrode
      Data line
      Headgear
      Strobe light
      Strobe light power supply
      User Manual
      Earth wire
      EEG bracket
      Aluminum block
      Optional
      SpO2 module, video module

      Physical characteristic


      Dimension: 186 mm(L)×186 mm(W)×89.2 mm(H)
      Weight: 750g
      Operational environment:
      Temperature: +5℃~+40℃
      Relative humidity: 25%~95% (no condensation)
      Atmospheric pressure: 700hPa~1060hPa
      Power supply: USB 5V DC
      Storage environment:
      Temperature:-20℃~+55℃
      Relative humidity: ≤90%
      Atmospheric pressure: 700hPa~1060hPa

       

      ADDITIONAL INFORMATION
      Color: Blue, Purple, White
      Size: 20, 24
      Material: 100% Polyester
      REVIEWS

      Customer Reviews

      Based on 1 review
      100%
      (1)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      M
      Marek Tchir
      Contec customer support experience

      I ordered the Digital 32 Channel EEG Machine and Mapping System product as a gift for my sick father, who's oy wish was to be able to measure his brain activity. When I received a package and open it with dad, we realized than unfortunately this was not the best option for us, since the preparation for usage of the equipment would be not very user friendly for my father considering his age and sickness. I informed the Contec customer support about the situation and the representative Bella helped me out with the possibility of returning the package. She was extraordinary help for me in my situation and answered all my questions immediately. I am extremely satisfied with your service and I would definitely order any kind of product again.

      Kind regards
      Marek Tchir

      GENERAL TAB

      RELATED PRODUCTS

      Customer Reviews

      Based on 1 review
      100%
      (1)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      0%
      (0)
      M
      Marek Tchir
      Contec customer support experience

      I ordered the Digital 32 Channel EEG Machine and Mapping System product as a gift for my sick father, who's oy wish was to be able to measure his brain activity. When I received a package and open it with dad, we realized than unfortunately this was not the best option for us, since the preparation for usage of the equipment would be not very user friendly for my father considering his age and sickness. I informed the Contec customer support about the situation and the representative Bella helped me out with the possibility of returning the package. She was extraordinary help for me in my situation and answered all my questions immediately. I am extremely satisfied with your service and I would definitely order any kind of product again.

      Kind regards
      Marek Tchir

      BACK TO TOP