Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
11)One-key print, convenient and fast to print the reports.
12)Perfect case management function.
13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.
14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
The oximeter is a device for measuring blood oxygen saturation. Insisting on using oximeter and monitoring blood oxygen content can effectively prevent the occurrence of danger. In case of hypoxia,...
1.Instructions (No battery) CMS50M Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and PR value through the finger, which provides advanced, non-invasive and scientific means...
Attention!The USB data cable in the suite is only used to transmit data to PC software, and cannot be used for power supply. Its voltage is not enough to keep...
CMS50D-BT is available in wired version and B&T version. This linked product is wired version(without B&T) CMS50D-BT Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and...
Attention!The USB data cable in the suite is only used to transmit data to PC software, and cannot be used for power supply. Its voltage is not enough to keep...
Software download link: www.dlsoftw.com Index code:05RK1069 Introduction ABPM50 is a handhold ambulatory blood pressure monitor, which is designed according to oscillography theory. The device could monitor human body blood pressure...
To US address, shipping from USA Warehouse To other countries, shipping from China IntroductionDynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by...
Instructions Principle of the CMS60D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used...