CONTEC TS13 Patient Monitor ICU HD Display 7 Para ETCO2 IBP ECG NIBP SPO2 Portable Monitor 13.3" High-definition Touch Screen

$1,699.00 $2,199.00
  • Barcode:
DESCRIPTION



1 Introduction

The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient's vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2, PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored..

2 Function

  • 13.3" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance.
  • Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition.
  • Luminous “ON / OFF” button design, convenient to operate at night.
  • Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters.
  • Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements.
  • Adopt high-performance processor, stable, reliable and fast to process information.
  • Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments.
  • Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).
  • With the functions of waveform freezing, holographic waveform storage and review.
  • Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage.
  • With HDMI expansion interface, the display screen can be connected according to clinical requirements.
  • Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.
  • Fanless design, ensures no noise and low power consumption during working.
  • 3-channel built-in recorder used to print real-time waveform is optional.
  • Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data.
  • Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff.

3 Performance

  • ECG
  • Lead type:

3-lead: I, II, III

5-lead: I, II, III, aVR, aVL, aVF, V

  • Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV
  • Scan speed: 5 mm/s, 25 mm/s, 50 mm/s
  • HR

Measurement and alarm range:

Adult: 15 ~ 300 bpm

Pediatric/neonate: 15 ~ 350 bpm

Resolution: 1 bpm

Accuracy: ± 1 % or ± 1 bpm, whichever is greater

  • ST-segment detection

Measurement and alarm range: - 2.0 mV ~ + 2.0 mV

Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater

Other range: unspecified

  • Arrhythmia analysis: 23 kinds
  • Pacemaker: yes
  • RESP
  • Measurement mode: R-F(RA-LL) impedance
  • Respiration rate:

Measurement range:

Adult: 0 rpm ~ 120 rpm

Pediatric/neonate: 0 rpm ~ 150 rpm

Resolution: 1 rpm

Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;

 0 ~ 6 rpm, unspecified

  • Apnea alarm:10 ~ 120 s, not alarm
  • Scan speed: 25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
  • NIBP
  • Measurement mode: Oscillometry
  • Working mode: Manual/AUTO/Continuous
  • Measurement interval in AUTO mode: 1min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h
  • Measurementperiod in Continuous mode: 5 minutes
  • Measurement and alarm range: 10~ 270 mmHg
  • Resolution: 1mmHg
  • Cuff pressure accuracy:± 3 mmHg
  • Measurement accuracy:

Maximal mean deviation: ± 5 mmHg

Maximal standard deviation: 8 mmHg

  • Over-pressure protection:

Adult mode: 297 ± 3 mmHg

Pediatric mode: 240 ± 3 mmHg

Neonatal mode: 147 ± 3 mmHg

  • CONTEC SpO2
  • Measurement range: 0% ~ 100 %
  • Resolution: 1%
  • Accuracy: 70% ~ 100 %, ± 2 %;

 0 % ~ 69 %, unspecified

  • PR

Measurement and alarm range: 25 ~ 250 bpm

Accuracy: ± 2 bpm or ± 2 %, whichever is greater

  • NellcorSpO2
  • Measurement range: 1% ~ 100 %
  • Measurement accuracy: 70% ~ 100 %: ± 2 % (adult / pediatric)

 70 % ~ 100 %: ± 3 % (neonate)

 0 % ~ 69 %: unspecified

  • NellcorPR

Measurement range: 20 ~ 300 bpm;

Measurement accuracy: 20 ~ 250 bpm, ±3 bpm;

 251 ~ 300 bpm: unspecified;

Upper limit of alarm: upper limit - 2 ~ 300 bpm;

Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm

  • MasimoSpO2
  • Measurement range: 1% ~ 100 %
  • Measurement accuracy:

70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion)

70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion)

1 % ~ 69 %: unspecified

  • MasimoPR

Measurement range: 25 ~ 240 bpm

Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion)

Upper limit of alarm: upper limit - 2 ~ 240 bpm

Lower limit of alarm: 25bpm ~ lower limit + 2 bpm

  • TEMP
  • Channel: dual-channel
  • Measurement range: 0~ 50 ℃
  • Resolution: 1℃
  • Accuracy: ±1 ℃
  • CO2
  • Measurement mode: mainstream or sidestream
  • CO2measurement range: 0 ~ 150 mmHg
  • CO2resolution: 1 mmHg: 0 ~ 69 mmHg

 0.25 mmHg: 70 ~ 150 mmHg

  • Accuracy:

0 ~ 40 mmHg: ± 2 mmHg

41 ~ 70 mmHg: ± 5 %

71 ~ 100 mmHg: ± 8 %

101 ~ 150 mmHg: ± 10 %

  • AwRRmeasurement range:

Sidestream: 2 ~ 120 rpm

Mainstream: 2 ~ 150 rpm

  • AwRRaccuracy: ± 1 rpm
  • Apnea alarm:yes
  • IBP
  • Channel: 4-channel
  • Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
  • Measurement and alarm range: -50~ 300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 % or 1 mmHg, whichever is greater
  • Power supply: 100~ 240 V ~  50/60 Hz
  • Safety class: class I, defibrillation-proof type CF applied part
  • Waterproof degree: IPX2


ADDITIONAL INFORMATION
Color: Blue, Purple, White
Size: 20, 24
Material: 100% Polyester
REVIEWS

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
M
Mogale Moyambo
Worth Every Penny

The Machine is top quality; it is solid and very well built. The display is large, numerical are easy to read.

Consistency and pin point accuracy of the machine gives the user the confidence.

Service from Contect was excellent and reassuring.

GENERAL TAB

RELATED PRODUCTS

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
M
Mogale Moyambo
Worth Every Penny

The Machine is top quality; it is solid and very well built. The display is large, numerical are easy to read.

Consistency and pin point accuracy of the machine gives the user the confidence.

Service from Contect was excellent and reassuring.

BACK TO TOP