Laptops are not included.
Introduction:
The equipment records bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis.
Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc.
Features:
Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time.
Neuro and muscle navigation system, convenient in selecting test part.
Powerful normal values system, contrast with normal data automatically.
Flexible software design, configure system parameters according to requirements.
High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise.
Integrative hardware system, compact in configuration and easy in moving.
Performance:
Main system part
A/D conversion resolution 16 Bit
Sampling ratio 200kHz
Analysis time 5-5000ms
Stimulating frequency 0.1-50Hz
Amplifier part
Four-channel
Sensitivity 0.05μV-20mV/Grid
Earth noise EMG <= 4μV(Vpp)
EP <=0.1μV(Vpp) (1000 times in average)
Common-mode rejection ratio >= 100dB
50Hz Ban wave setting:
Upper limit for Filter-frequency 20kHz
Lower limit for Filter-frequency 1Hz
Gain amplifies 25 times-400000 times
Stimulator part
Constant current 0.2-100mA
Pulse width 50-1000μS
Short circuit and overloading protection
Auditory Stimulator
Stimulation wave 40Hz Short, Sound Stim
Stimulation polarity nondense wave, dense wave and alternant wave.
Sound strength 40-120db (5db per level)
Stimulation mode left, right, left & right
Frequency of 40Hz carrier wave 500-8000Hz
Visual stimulator
Mode tessellation, horizontal bar and vertical bar.
Stimulation view all-view, half-view and quarter-view
Resolution 3x4, 6x8, 12x16, 24x32, 48x64
Flash stimulator all quench,left light,right light,l&r light
Physical characteristic:
Dimension 420mm*350mm*46mm(L×W×H)
Net weight 6KG
Accessories:
User Manual (GB only)on request for other Language
Disk
Power Cord
Power Adapter
USB Cable
Audio Cable
Earth Cable
Current Stimulator
One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm
Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm
Concentric Needle Connecting Wire
1mm Connecting Lead Wire
Disc Electrode
Ring Electrode
Surface Electrode
Ground Electrode(Include lead cable)
One-off Unipolar Needle Electrode
From 1 to 2 Conversion Cable
Surface Electrode Conversion Cable
Fuse 0.1A/250V, 5*20mm
Fuse F1.6AL250V, 5*20mm
Flash Stimulator
Audio Stimulator