CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag
  • SKU:
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

CONTEC CMS8000 VET ICU Veterinary Patient Monitor Vital Signs Animal CO2 capnograph,Printer,Bag

$898.00
  • Barcode:
DESCRIPTION

Introduction

The CMS8000VET Veterinary Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements. It adopts 100-240V~,50/60Hz for power supply, 12.1'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system. 

This device can monitor such parameters as ECG, RESP, NIBP, SpO2 and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for moving.


Functions

Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

1)ECG   Heart rate (HR)

      ECG waveform 

      Arrhythmia and ST-segment analysis

2)RESP   Respiration rate(RR)

      Respiration waveform

3)SpO2   Oxygen saturation(SpO2)

      Plethysmogram(PLETH) waveform

      Pulse rate(PR)

      Bar graph

4)NIBP   Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)

5)TEMP   T1, T2, TD

It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc


Features

1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).

2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.

3)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.

4)Operation mode: keys and buttons.

5)Display up to 8-channel waveform on one screen.

6)Display 7-lead ECG waveform on one screen, and with ECG step function.

7)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.

8)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.

9)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.

10)Drug concentration calculation and titration table functions. 

11)Print trend table data with one-key.

12)Connect to Central Monitoring System by 3G, WiFi or wired mode.

13)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.

14)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).


Performance

▲ECG

Lead mode:       3-lead or 5-lead

Lead selection:      I, II, III, aVR, aVL, aVF, V

Waveform:       5-lead, 2-channel

      3-lead, 1-channel

Gain:        2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV

Scan speed:       12.5mm/s, 25 mm/s, 50 mm/s

HR: 

Measurement and alarm range:  15~350bpm

Accuracy:     ±1% or ±1bpm, whichever is greater

Alarm accuracy:     ± 2 bpm

Resolution:      1 bpm

ST-segment monitoring:

Measurement and alarm range:  -2.0mV~+2.0mV

Accuracy:     -0.8mv~+0.8mv  ±0.04mv or ±10%, whichever is greater 

     Other range: unspecified 

Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, 

PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Pacemaker:       yes

▲RESPIRATION

Method:       R-F(RA-LL) Impedance 

Respiration rate: 

Measurement and alarm range: 0~150rpm

Resolution:     1 rpm

Measurement accuracy:   ±2 rpm

Alarm accuracy:    ±3 rpm

Apnea alarm:     10~40s

Scan speed:     6.25 mm/s, 12.5 mm/s, 25 mm/s

▲NIBP

Method:       Oscillometry

Mode:       Manual/AUTO/STAT 

Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes

Measurement period in STAT mode: 5 minutes

Measurement and alarm range:  10 ~ 270 mmHg

Resolution:      1 mmHg

Cuff pressure accuracy:    ±3 mmHg

Measurement accuracy:

Maximal mean error:   ±5 mmHg

Maximal standard deviation:  8mmHg

Over-pressure protection:

Other mode:     297±3 mmHg

 Dog mode:     240±3 mmHg

 Cat mode:     147±3 mmHg

▲SpO2

Measurement and alarm range:  0 ~ 100%

Resolution:      1%

Measurement accuracy:    70%~100%: ±2%; 

 0%~69%: unspecified

▲PR

Measurement and alarm range:  30 ~ 250 bpm

Measurement accuracy:    ±2 bpm or ±2%, whichever is greater

▲TEMP

Channel:       dual-channel

Measurement and alarm range:  0 ~ 50℃

Resolution:      0.1 ℃

Accuracy:      ±0.1 ℃

▲Power supply:    100-240V~,50/60Hz

▲Safety classification:   Class I, type CF defibrillation-proof applied part


Accessories

1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M)

2)General digital SpO2 sensor extension cable (2M)

3)Neonatal capsule single tube repeatable cuff (6-11cm)

4)NIBP extension tube

5)5-lead ECG lead cable (American-Standard)

6)ECG veterinary clip (*5)

7)Transvaginal TEMP probe

8)Power cord 

9)User Manual 


Physical characteristic

Dimension: 314mm(L)×145mm(W)×264mm(H)

Weight: 3.9 Kg

ADDITIONAL INFORMATION
Color: Blue, Purple, White
Size: 20, 24
Material: 100% Polyester