No Products in the Cart
1.Introduction
CMS5000VET Veterinary Monitor adopts Oscillometry technology, also called Oscillography technology for NIBP measuring, and adopts Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2 and Pulse rate (PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for animal hospitals and family.
2.Features
âBe applicable for NIBP and SpO2 monitoring of cat, dog and other animals, easy operation and high cost performance.
âBuilt-in rechargeable lithium polymer battery for uninterrupted monitoring.
âCompact and flexible appearance, simple operation, easy for carrying.
âWith user-friendly interface.
âDisplay with 2.4'' (320Ă240) color TFT LCD and blue highlight LED.
âVisual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
âUnique Flash memory, storage for up to 2000 NIBP data or SpO2 data within 48-hour.
âConvenient and quick in inquiring measurement data.
3.Performance
NIBP monitoring
âMeasurement method: Oscillometry
âMeasurement mode: manual/auto.
âAuto measurement interval: adjustable from 1 to 255 minutes.
âResolution: 1mmHg.
âAccuracy: Maximum Mean deviation±5mmHg, Maximum Standard deviationâ€8mmHg.
âSelf-check function.
âOverpressure protection: double protection for software and hardware.
âMeasurement range: 10mmHgïœ270mmHg.
SpO2 monitoring
âContinuous real-time measuring.
âAdopt digital SpO2 technology, which has strong anti-interference capability.
âReal-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate (PR) trend graph.
âTrend graph with the function of adaptive scaling
1.SpO2 Measuring
Range: 0%ïœ100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%ïœ100%, and unspecified in stage of less than 70%.
2.Pulse Rate Measuring
Range: 30bpmïœ250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
3.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
4.Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
4.Accessories
Power cord
Digital DB7 animal tongue clip SpO2 probe
Integrated digital SpO2 probe extension cable
Neonatal capsule single tube repeatable cuffÂ
NIBP extension tube
User Manual ïŒGB onlyïŒon request for other Language
5.Physical characteristic
Dimension: 232 mm(L)Ă198 mm(W)Ă75 mm(H)
Weight: 1.15kg