CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6
CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6
CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6
CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6
CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6
  • SKU: 3.05.064.04.001
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

CONTEC TS15 Patient Monitor ICU HD Display 7 Para ECG NIBP SPO2 ETCO2 IBP Portable Monitor 15.6" High-Definition Touch Screen

$2,199.00 $2,699.00
  • Barcode:
DESCRIPTION



1 Introduction

The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient's vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2, PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored..

2 Function

  • 15.6" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance.
  • Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition.
  • Luminous “ON / OFF” button design, convenient to operate at night.
  • Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters.
  • Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements.
  • Adopt high-performance processor, stable, reliable and fast to process information.
  • Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments.
  • Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).
  • With the functions of waveform freezing, holographic waveform storage and review.
  • Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage.
  • With HDMI expansion interface, the display screen can be connected according to clinical requirements.
  • Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.
  • Fanless design, ensures no noise and low power consumption during working.
  • 3-channel built-in recorder used to print real-time waveform is optional.
  • Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data.
  • Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff.

3 Performance

  • ECG
  • Lead type:

3-lead: I, II, III

5-lead: I, II, III, aVR, aVL, aVF, V

  • Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV
  • Scan speed: 5 mm/s, 25 mm/s, 50 mm/s
  • HR

Measurement and alarm range:

Adult: 15 ~ 300 bpm

Pediatric/neonate: 15 ~ 350 bpm

Resolution: 1 bpm

Accuracy: ± 1 % or ± 1 bpm, whichever is greater

  • ST-segment detection

Measurement and alarm range: - 2.0 mV ~ + 2.0 mV

Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater

Other range: unspecified

  • Arrhythmia analysis: 23 kinds
  • Pacemaker: yes
  • RESP
  • Measurement mode: R-F(RA-LL) impedance
  • Respiration rate:

Measurement range:

Adult: 0 rpm ~ 120 rpm

Pediatric/neonate: 0 rpm ~ 150 rpm

Resolution: 1 rpm

Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;

 0 ~ 6 rpm, unspecified

  • Apnea alarm:10 ~ 120 s, not alarm
  • Scan speed: 25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
  • NIBP
  • Measurement mode: Oscillometry
  • Working mode: Manual/AUTO/Continuous
  • Measurement interval in AUTO mode: 1min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h
  • Measurementperiod in Continuous mode: 5 minutes
  • Measurement and alarm range: 10~ 270 mmHg
  • Resolution: 1mmHg
  • Cuff pressure accuracy:± 3 mmHg
  • Measurement accuracy:

Maximal mean deviation: ± 5 mmHg

Maximal standard deviation: 8 mmHg

  • Over-pressure protection:

Adult mode: 297 ± 3 mmHg

Pediatric mode: 240 ± 3 mmHg

Neonatal mode: 147 ± 3 mmHg

  • CONTEC SpO2
  • Measurement range: 0% ~ 100 %
  • Resolution: 1%
  • Accuracy: 70% ~ 100 %, ± 2 %;

 0 % ~ 69 %, unspecified

  • PR

Measurement and alarm range: 25 ~ 250 bpm

Accuracy: ± 2 bpm or ± 2 %, whichever is greater

  • NellcorSpO2
  • Measurement range: 1% ~ 100 %
  • Measurement accuracy: 70% ~ 100 %: ± 2 % (adult / pediatric)

 70 % ~ 100 %: ± 3 % (neonate)

 0 % ~ 69 %: unspecified

  • NellcorPR

Measurement range: 20 ~ 300 bpm;

Measurement accuracy: 20 ~ 250 bpm, ±3 bpm;

 251 ~ 300 bpm: unspecified;

Upper limit of alarm: upper limit - 2 ~ 300 bpm;

Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm

  • MasimoSpO2
  • Measurement range: 1% ~ 100 %
  • Measurement accuracy:

70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion)

70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion)

1 % ~ 69 %: unspecified

  • MasimoPR

Measurement range: 25 ~ 240 bpm

Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion)

Upper limit of alarm: upper limit - 2 ~ 240 bpm

Lower limit of alarm: 25bpm ~ lower limit + 2 bpm

  • TEMP
  • Channel: dual-channel
  • Measurement range: 0~ 50 ℃
  • Resolution: 1℃
  • Accuracy: ±1 ℃
  • CO2
  • Measurement mode: mainstream or sidestream
  • CO2measurement range: 0 ~ 150 mmHg
  • CO2resolution: 1 mmHg: 0 ~ 69 mmHg

 0.25 mmHg: 70 ~ 150 mmHg

  • Accuracy:

0 ~ 40 mmHg: ± 2 mmHg

41 ~ 70 mmHg: ± 5 %

71 ~ 100 mmHg: ± 8 %

101 ~ 150 mmHg: ± 10 %

  • AwRRmeasurement range:

Sidestream: 2 ~ 120 rpm

Mainstream: 2 ~ 150 rpm

  • AwRRaccuracy: ± 1 rpm
  • Apnea alarm:yes
  • IBP
  • Channel: 4-channel
  • Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
  • Measurement and alarm range: -50~ 300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 % or 1 mmHg, whichever is greater
  • Power supply: 100~ 240 V ~  50/60 Hz
  • Safety class: class I, defibrillation-proof type CF applied part
  • Waterproof degree: IPX2


ADDITIONAL INFORMATION
Color: Blue, Purple, White
Size: 20, 24
Material: 100% Polyester