  • SKU: 3.03.007.04.001
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

CONTEC ECG300GT Touch screen Electrocardiograph,Digital 3 Channel 12 lead EKG+Printer

$500.00 $559.00
  • Barcode:
DESCRIPTION

 

Introduction

ECG300GT is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by thermal printing system. The device can be operated by both touch screen and keys. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.

Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, auto 3-2+1, auto 3-2, auto 1x12+1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Build-in large capacity memory stores at least to 1000 cases, which is convenient for doctor to review case and statistic.
6)Multi- language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian language) interface and report.

Performance
Input mode: floating and defibrillation protection
Lead: Standard 12-lead
Patient leakage current: <10 µA
Input impedance: ≥2.5MΩ
Frequency response:
Rated input amplitude    Input frequency and waveform    Relative output response
1.0    0.67Hz~40Hz, Sine wave    ±10%a
0.5    40Hz~100Hz, Sine wave    +10 %, -30 %a
0.25    100Hz~150Hz, Sine wave    +10 %, -30 %a
0.5    150 Hz ~ 500 Hz, Sine wave    +10 %, -100 %a
1.5    ≤1Hz,200ms, Triangle wave    +0 %, -10 %b
a relative to 10Hz   b relative to 200 ms
Time constant:≥ 3.2s
CMRR: >105dB
Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter
Recording way: thermal printing system
Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper
Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%
Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV
Recording mode: auto mode, rhythm mode and manual mode
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Safety classification: Class I, type CF defibrillation-proof applied part
Polarization resistance voltage: ±610mV
Noise level: ≤12 µVp-p
ECG signal input sampling frequency: 32 kHz
Waveform data processing sampling frequency: 1 kHz
Sampling accuracy: 24-bit
The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected
Pacing detection channel: standard II
Accuracy of input signal: ±5%
Amplitude quantization: ≤5µV/LSB
Dimension: 315 mm(L)×215 mm(W)×77 mm(H)
Weight: 1.6 kg
Interchannel time deviation: <100 µs
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/3500mAh rechargeable lithium battery
Degree of protection against ingress of liquid: IPX0
Working mode: continuous working

Accessories
Standard configuration:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual

Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700 hPa~1060 hPa
Transport and storage environment
Temperature: -20 ℃~+55 ℃
Relative humidity: ≤95%
Atmospheric pressure: 500 hPa~1060 hPa
Dimension: 315mm(L)×215mm(W)×77mm(H)
Weight: 1.6Kg

Optional configuration
Refer to BOM.

Certification
CE.
ADDITIONAL INFORMATION
Color: Blue, Purple, White
Size: 20, 24
Material: 100% Polyester