to US address, shipping from USA Warehouse to other countries, shipping from China
Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
11)One-key print, convenient and fast to print the reports.
12)Perfect case management function.
13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.
14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
Introduction PM50 is a multi-functional patient monitor that can monitor BP and SpO2 at the same time. Realizing long time monitoring of dynamic blood pressure, the device is widely applicable...
To US address, shipping from USA Warehouse To other countries, shipping from China IntroductionDynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by...
To US address, shipping from USA Warehouse To other countries, shipping from China Introduction The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and...
Note: products shipped to the United States do not have automatic analysis function. Introduction ECG90A is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the...
Introduction MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it...
To US address, shipping from USA Warehouse To other countries, shipping from China Introduction Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for...
Note: products shipped to the United States do not have automatic analysis function. Introduction USA Warehouse Fedex shipping ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously...
Note: products shipped to the United States do not have automatic analysis function. Introduction ECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal...