Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
11)One-key print, convenient and fast to print the reports.
12)Perfect case management function.
13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.
14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
1.Color HD Display screen The 7-inch high-resolution full-fit color touch screen is adopted to provide users with good visual effects, with clearer waveforms and more reliable results. 2.Key touch combination...
1.Colorful HD Display screen The 10.1-inch full-fit color touch screen with a resolution of up to 1280*800 provides users with good visual effects, richer display content, clearer waveforms, and more...
1.Colorful HD Display screen The 10.1-inch full-fit color touch screen with a resolution of up to 1280*800 provides users with good visual effects, richer display content, clearer waveforms, and more...
Instructions The device can be worn on the forehead or sternum area to remind the user to adjust the sleeping position and train the snoring people to sleep in the...
The sampling tube is disposable. Please do not reuse it. The service time of each tube is recommended to be less than half an hour. If it is more than...
Introduction TP500 Infrared Thermometer is a body temperature measurement device, powered by two “AAA” batteries, which has abundant measurement functions. It can quickly measure the body temperature without contact, which...
Portable Single-sided Stethoscope COTNEC SC11 Professional Cardiology 2021 Newest Intended purpose It is used to collect and amplify the sound inside body organs like heart, lung, arteries, vein, etc., which...
Brief introduction Double Dual Head Stethoscope Complete with both diaphragm and bell features Suitable for doctors, nurses, mothers, students etc * Made from brass this is a two-sided chest piece...
24h ECG Holter CONTEC TLC5000 12 lead EKG Monitor free PC Software Analyzer