CONTEC TS1 Patient Monitor+free thermometer 5 Para ECG NIBP SPO2 PR TEMP Portable Monitor 5
CONTEC TS1 Patient Monitor+free thermometer 5 Para ECG NIBP SPO2 PR TEMP Portable Monitor 5
CONTEC TS1 Patient Monitor+free thermometer 5 Para ECG NIBP SPO2 PR TEMP Portable Monitor 5
  • SKU: 3.05.058.04.002+3.11.027.04.012
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

CONTEC TS1 Patient Monitor+free thermometer 5 Para ECG NIBP SPO2 PR TEMP Portable Monitor 5" touch screen

$799.00 $1,199.00
  • Barcode:
DESCRIPTION

CONTEC new product!!!

1 Introduction

The monitor is used to monitor, display, check, store, alarm and transmit many physiological parameters, including ECG (3/5/12 lead, arrhythmia analysis, ST segment analysis and HR ), RESP, SpO2, PR, NIBP, TEMP and IBP, etc. It is applicable for use by adult, children and neonate.

The monitor can be used in medical institutions or during transport monitoring inside/outside the hospital environment, it is used by clinical professionals or under their guidance or professionals via training, it is not suitable for use in family.

2 Function

  • 5" touch screen, easy and convenient to operate, automatic lock screen function prevents misoperation.
  • Portable design (weight <0 kg), flexible to transport.
  • Multi - interface selection, convenient to observe patient’s data trend.
  • Degree of protection provided by enclosure complies with IEC/EN 60529, waterproof degree: IP44
  • Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
  • Built-in large-capacity battery, meets the requirements of long-term operation.

3 Performance

  • ECG
  • Lead type:

3-lead: I, II, III

5-lead: I, II, III, aVR, aVL, aVF, V

  • Waveform

3-lead: 1 channel

5-lead: 2-channel

  • Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV
  • Scan speed: 5 mm/s, 25 mm/s, 50 mm/s
  • HR

Measurement and alarm range:

Adult: 15 ~ 300 bpm

Pediatric/neonate: 15 ~ 350 bpm

Resolution: 1 bpm

Accuracy: ± 1 % or ± 1 bpm, whichever is greater

Alarm error: ± 2 bpm

  • ST-segment detection

Measurement and alarm range: - 2.0 mV ~ + 2.0 mV

Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater

Other range: unspecified

  • Arrhythmia analysis: 13 kinds
  • Pacemaker: yes
  • RESP
  • Measurement mode: R-F(RA-LL) impedance
  • Respiration rate:

Measurement range: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;

 0 ~ 6 rpm, unspecified

  • Apnea alarm: 10~ 40 s
  • Scan speed: 12.5 mm/s, 25 mm/s
  • NIBP
  • Measurement mode: Oscillometry
  • Working mode: Manual/AUTO/Continuous
  • Measurement interval in AUTO mode: 1/ 2 / 3/ 4 / 5 / 10 / 15 / 30 / 60 / 90 / 120 / 240 /480 /960 minutes
  • Measurementperiod in Continuous mode: 5 minutes
  • Measurement and alarm range: 10~ 270 mmHg
  • Resolution: 1mmHg
  • Cuff pressure accuracy: ±3 mmHg
  • Measurement accuracy:

Maximal mean deviation: ± 5 mmHg

Maximal standard deviation: 8 mmHg

  • Over-pressure protection:

Adult mode: 297 ± 3 mmHg

Pediatric mode: 240 ± 3 mmHg

Neonatal mode: 147 ± 3 mmHg

  • SpO2
  • Measurement and alarm range: 0~ 100%
  • Resolution: 1%
  • Measurement accuracy: 70% ~ 100 %: ± 2 %;

0 % ~ 69 %: unspecified

  • PR
  • Measurement and alarm range: 25 ~ 250bpm
  • Accuracy: ±2 bpm or ± 2 %, whichever is greater
  • TEMP
  • Channel: dual-channel
  • Measurement and alarm range: 0 ~ 50 ℃
  • Resolution: 1℃
  • Accuracy: ±1 ℃
  • IBP
  • Channel: dual-channel
  • Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
  • Measurement and alarm range: -10 ~ 300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 % or 1 mmHg, whichever is greater
  • Power supply: 100 ~ 240 V ~ 50 / 60 Hz (adapter output: DC 12 V)
  • Safety class: class I, defibrillation-proof type CF applied part
  • Waterproof degree: IP44
  • 4 Accessories

  • A free thermometer

    Category

    Accessory name

    Main unit

    TS1 main unit

    ECG cable

    5-lead, American standard, TPU

    SpO2 probe (integrated)

    Digital fingertip SpO2 probe for adult  (CMS-N-SPO2 6P, 3M, yellow)

    TEMP probe

    R25=2.252K TEMP probe, skin surface type, CMS-N-TEMP 2P, PVC, L=3M

    NIBP cuff

    BP extension tube, L=3M

    Adult cuff (25 ~ 35 cm)

  • 5 Physical characteristic

  • Dimension: 142 mm × 67 mm × 102 mm
  • Weight: < 1 kg

    6 Optional configuration

    IBP

ADDITIONAL INFORMATION
Color: Blue, Purple, White
Size: 20, 24
Material: 100% Polyester