PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR - contechealth
Sold Out
  • Availability:Out of stock

PM60D Patient Monitor 4 Parameters Vital Signs Monitor ECG NISP SPO2 PR

$449.00
  • Barcode: 658126898171
DESCRIPTION

shipping from China 

PM60D Patient Monitor is a portable device, designs with modularization, and can be freely combined for single-parameter or multi-parameter monitor. And it can be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.

Features

◆ All-round monitoring for adult, pediatric and neonatal.
◆ 3.5'' (320×240) TFT LCD.
◆ Operate with button and touch screen.
◆ Review of data list and trend graph.
◆ Configuring interface as user's requirements.
◆ Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set.
◆ Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
◆ Selective SD card for storing 72-hour data.


Performance


● ECG
◆ 3-lead and 5-lead are optional.
◆ Waveform display: dual-lead/full-lead
◆ Gain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
◆ Measurement range for Heart rate(HR): 30bpm~300bpm, error: ±1bpm or ±1%, whichever is greater.
◆ Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
◆ Input current: ≤0.1μA
◆ Enduring polarization voltage: ±300mV, sensitivity range: ±5%.
◆ CMRR: filter mode(surgery, monitoring)≥80dB
◆ Frequency response: 1~75Hz(+0.4dB,-3dB)
◆ Low-frequency characteristic: time constant≥3.2s
◆ Analysis function: heart rate, arrhythmia analysis, S-T segment analysis
◆ S-T segment range: -2.0mV~2.0mV


● Blood Pressure
◆ Measurement method: Oscillometry
◆ Measurement mode: manual/auto/continuous.
◆ Auto measurement interval: adjustable from 1 to 90 minutes.
◆ Resolution: 1mmHg.
◆ Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
◆ Self-check function.
◆ Overpressure protection: double protection for software and hardware.


1) Range
Adult:
    Systolic pressure: 40mmHg~270mmHg
    Mean pressure: 20mmHg~235mmHg
    Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
    Systolic pressure: 40mmHg~200mmHg
    Mean pressure: 20mmHg~165mmHg
    Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
    Systolic pressure: 40mmHg~135mmHg
    Mean pressure: 20mmHg~110mmHg
    Diastolic Pressure: 10mmHg~100mmHg


2) Upper and lower limit of alarm
Adult:
    Systolic pressure: 40mmHg~270mmHg
    Mean pressure: 20mmHg~235mmHg
    Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
    Systolic pressure: 40mmHg~200mmHg
    Mean pressure: 20mmHg~165mmHg
    Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
    Systolic pressure: 40mmHg~135mmHg
    Mean pressure: 20mmHg~110mmHg
    Diastolic Pressure: 10mmHg~100mmHg


● SpO2 monitoring
◆ Continuous real-time measuring.
◆ Adopt digital SpO2 technology, which has strong anti-interference capability.
◆ Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
◆ Trend graph with the function of adaptive scaling
◆ Standard finger-clip probe for adult , binding probe for neonatal is optional.
1) SpO2 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2) Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

Accessories

◆ A power cord
◆ A power adapter
◆ An ECG lead wire
◆ A SpO2 probe
◆ An adult NIBP cuff
◆ An extending tube for blood pressure

Physical characteristic of host


Dimension: 92(L)×22(W)×82(H)mm
Weight: 400g(including battery)